MITSUBISHI ELECTRIC FR-S520 User Manual

Page 188

Advertising
background image

179

Data Code

Func-

tion

Parameter

Number

Name

Read Write

Computer

Link Data

Setting

Increments *

Link Parameter

Extension

Setting

(Data Code

7F/FF)

48

Output current detection
level

30

B0

0.1%

0

49

Output current detection
signal delay time

31

B1

0.1s

0

50

Zero current detection
level

32

B2

0.1%

0

Cur

rent

det

ec

ti

on

51

Zero current detection
time

33

B3

0.01s

0

52

Control panel display
data selection

34

B4

1

0

53

Frequency setting
operation selection

35

B5

1

0

54

FM (AM) terminal
function selection

36

B6

1

0

55

Frequency monitoring
reference

37

B7

0.01Hz

0

Di

s

p

la

y f

unc

ti

ons

56

Current monitoring
reference

38

B8

0.01A

0

57

Restart coasting time

39

B9

0.1s

0

A

u

to

m

a

tic

re

sta

rt

func

ti

ons

58

Restart cushion time

3A

BA

0.1s

0

Addi

ti

onal

func

ti

on

59

Remote setting function
selection/Frequency
setting storage function
selection

3B

BB

1

0

60

RL terminal function
selection

3C

BC

1

0

61

RM terminal function
selection

3D

BD

1

0

62

RH terminal function
selection

3E

BE

1

0

63

STR terminal function
selection

3F

BF

1

0

64

RUN terminal function
selection

40

C0

1

0

Ter

m

inal

func

ti

ons

se

le

ctio

n

65

A, B, C terminal function
selection

41

C1

1

0

66

Retry selection

42

C2

1

0

67

Number of retries at
alarm occurrence

43

C3

1

0

68

Retry waiting time

44

C4

0.1s

0

69

Retry count display erase

45

C5

1

0

70

Soft-PWM setting

46

C6

1

0

Oper

at

ion s

e

le

c

ti

o

n

func

ti

ons

71

Applied motor

47

C7

1

0

Advertising