MITSUBISHI ELECTRIC FR-S520 User Manual

Page 42

Advertising
background image

33

1

Multi-Speed Setting

Terminal Input

Speed REX-

SD*

RH-

SD

RM-

SD

RL-

SD

Parameter

Set Frequency

Range

Remarks

Speed 1

(high

speed)

OFF ON OFF OFF

Pr. 4

0 to 120Hz

———————

Speed 2

(middle

speed)

OFF OFF ON OFF

Pr. 5

0 to 120Hz

———————

Speed 3

(low

speed)

OFF OFF OFF ON

Pr. 6

0 to 120Hz

———————

Speed 4 OFF OFF ON ON

Pr. 24

0 to 120Hz, - - - Pr. 6 setting when Pr. 24="- - -"

Speed 5 OFF ON OFF ON

Pr. 25

0 to 120Hz, - - - Pr. 6 setting when Pr. 25="- - -"

Speed 6 OFF ON ON OFF

Pr. 26

0 to 120Hz, - - - Pr. 5 setting when Pr. 26="- - -"

Speed 7 OFF ON ON ON

Pr. 27

0 to 120Hz, - - - Pr. 6 setting when Pr. 27="- - -"

Speed 8 ON OFF OFF OFF

Pr. 80

0 to 120Hz, - - - 0Hz when Pr. 80="- - -"

Speed 9 ON OFF OFF ON

Pr. 81

0 to 120Hz, - - - Pr. 6 setting when Pr. 81="- - -"

Speed 10 ON OFF ON OFF

Pr. 82

0 to 120Hz, - - - Pr. 5 setting when Pr. 82="- - -"

Speed 11 ON OFF ON ON

Pr. 83

0 to 120Hz, - - - Pr. 6 setting when Pr. 83="- - -"

Speed 12 ON ON OFF OFF

Pr. 84

0 to 120Hz, - - - Pr. 4 setting when Pr. 84="- - -"

Speed 13 ON ON OFF ON

Pr. 85

0 to 120Hz, - - - Pr. 6 setting when Pr. 85="- - -"

Speed 14 ON ON ON OFF

Pr. 86

0 to 120Hz, - - - Pr. 5 setting when Pr. 86="- - -"

Speed 15 ON ON ON ON

Pr. 87

0 to 120Hz, - - - Pr. 6 setting when Pr. 87="- - -"

External

setting

OFF OFF OFF OFF

Frequency

setting

potentiometer

0 to max. setting

———————

*When using the REX signal, a reverse rotation start cannot be made by the

external command.

10

2

5

Power supply

Forward rotation

Multi-speed
selection

Frequency
setting
potentiometer

Inverter

R<L

1

>

S<N>

T

U

V

W

STF

REX

RH

RM

RL

SD

IM

Motor

*2

*1

Multi-Speed Operation Connection Example

REMARKS

*1: When the frequency setting potentiometer is connected, the input signal of the

frequency setting potentiometer is ignored if the multi-speed select signal is
switched on. (This also applies to the 4 to 20mA input signal.)

*2: For a reverse rotation start, set Pr. 63 to "- - -" (factory setting).

Advertising