MITSUBISHI ELECTRIC FR-S520 User Manual

Page 59

Advertising
background image

50

Func-

tion

Pa-

rame-

ter

Indica-

tion

Name

Setting Range

Minimum

Setting

Increments

Factory

Setting

Refer

To:

Cus-

tomer

Setting

60

RL terminal
function
selection

1

0

88

61

RM terminal
function
selection

1

1

88

62

RH terminal
function
selection

1

2

88

63

STR terminal
function
selection

0: RL, 1: RM, 2: RH,

3: RT, 4: AU, 5: STOP,

6: MRS, 7: OH,

8: REX, 9: JOG,

10: RES, 14: X14,

16: X16,

- - -: STR (May be

assigned to the STR

terminal only)

1

- - -

88

64

RUN terminal
function
selection

1

0

90

65

A, B, C
terminal
function
selection

0: RUN, 1: SU, 3: OL,
4: FU, 11: RY, 12: Y12,
13: Y13, 14: FDN,
15: FUP, 16: RL,
98: LF, 99: ABC

1

99

90

66

Retry selection

0: OC1 to 3, OV1 to 3,

THM, THT, GF,
OHT, OLT, PE, OPT

1: OC1 to 3,
2: OV1 to 3,
3: OC1 to 3, OV1 to 3

1

0

91

67

Number of
retries at alarm
occurrence

0: No retry
1 to 10:
Without alarm output
during retry operation
101 to 110:
With alarm output
during retry operation

1

0

91

68

Retry waiting
time

0.1 to 360s

0.1s

1s

91

69

Retry count
display erase

0: Cumulative count

erase

1

0

91

70 *

Soft-PWM
setting

0: Soft-PWM invalid,
1: Soft-PWM valid

1

1

92

71

Applied motor

0: Thermal characteristic

for standard motor

1: Thermal characteristic

for Mitsubishi
constant-torque motor

1

0

93

72 *

PWM
frequency
selection

0 to 15

1

1

92

Ter

m

in

al

f

u

nc

tio

n

s

e

le

c

ti

o

n

73

0-5V/0-10V
selection

0: For 0 to 5VDC input
1: For 0 to 10VDC input

1

0

93

Pammet

e

r Li

s

t