51

2

Func-

tion

Pa-

rame-

ter

Indica-

tion

Name

Setting Range

Minimum

Setting

Increments

Factory

Setting

Refer

To:

Cus-

tomer

Setting

74

Input filter time
constant

0: 2-step moving

average processing

1 to 8:

Exponential average
value of 2n at the
setting of n

1

1

94

75 *

Reset
selection/PU
stop selection

0: Reset normally

enabled/PU stop
key disabled

1: Enabled at alarm

occurrence only/PU
stop key disabled

14: Reset normally

enabled/normally
decelerated to stop

15: Enabled at alarm

occurrence
only/normally
decelerated to stop

1

14

94

76

Cooling fan
operation
selection

0: Operation started at

power-on

1: Cooling fan ON/OFF

control

1

1

96

77 *

Parameter
write disable
selection

0: Write is enabled only

during a stop

1: Write disabled

(except some
parameters)

2: Write during

operation enabled

1

0

97

Op

er

at

io

n s

e

le

c

ti

o

n f

u

nc

ti

ons

78

Reverse
rotation
prevention
selection

0: Both forward rotation

and reverse rotation
enabled,

1: Reverse rotation

disabled,

2: Forward rotation

disabled

1

0

98

80 *

Multi-speed
setting (speed
8)

0 to 120Hz, - - -

0.1Hz

- - -

61

81 *

Multi-speed
setting (speed
9)

0 to 120Hz, - - -

0.1Hz

- - -

61

82 *

Multi-speed
setting (speed
10)

0 to 120Hz, - - -

0.1Hz

- - -

61

Mul

ti-

s

p

e

e

d

op

er

at

ion

fu

nc

tio

n

83 *

Multi-speed
setting (speed
11)

0 to 120Hz, - - -

0.1Hz

- - -

61

Pammet

e

r Li

s

t

Advertising