2 pwm carrier frequency [p70] [p72, Caution, 2 pwm carrier frequency – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 101

Advertising
background image

92

CAUTION

The cumulative number in Pr. 69 is incremented by "1" when retry operation is

regarded as successful, i.e. when normal operation is continued without the
protective function (major fault) activated during a period four times longer than
the time set in Pr. 68.

If the protective function (major fault) is activated consecutively within a period four

times longer than the above waiting time, the control panel may show data different
from the most recent data or the parameter unit (FR-PU04) may show data different
from the first retry data. The data stored as the error reset for retry is only that of the
protective function (major fault) which was activated the first time.

When an inverter alarm is reset by the retry function at the retry time, the stored

data of the electronic overcurrent protection, etc. are not cleared. (Different from
the power-on reset.)

CAUTION

When you have selected the retry function, stay away from the motor and

machine unless required. They will start suddenly (after the reset time has
elapsed) after occurrence of an alarm.
When you have selected the retry function, apply in easily visible places the
CAUTION seals supplied to the instruction manual (basic).

2

.10.2

PWM carrier frequency

You can change the motor sound.

Parameter

Name

Factory

Setting

Setting

Range

Remarks

70

Soft-PWM setting

1

0, 1

72

PWM frequency
selection

1

0 to 15

Setting is enabled when
Pr. 30 = "1"

REMARKS

By parameter setting, you can select Soft-PWM control which changes the motor
tone.
Soft-PWM control changes motor noise from a metallic tone into an unoffending
complex tone.

<Setting>

Parameter

Number

Setting

Description

0

Soft-PWM invalid

70

1

When any of "0 to 5" is set in Pr. 72, Soft-PWM is made valid.

72

0 to 15

PWM carrier frequency can be changed.
The setting displayed is in [kHz].
Note that 0 indicates 0.7kHz and 15 indicates 14.5kHz.

REMARKS

An increased PWM frequency will decrease motor noise but noise and leakage
current will increase. Take proper action (Refer to pages 18).
Metallic sound may be generated from the motor at sudden deceleration but it is not a
fault.

Advertising
This manual is related to the following products: