2 layout and wiring of main circuit terminals, Caution, Remarks – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 12

Advertising
background image

3

1

CAUTION

To prevent a malfunction due to noise, keep the signal cables more than 10cm (3.94inches)
away from the power cables.

FR-S520S-0.1K to 1.5K (-R) (-C)
FR-S510W-0.1K to 0.75K (-R)

Power supply

NFB

R
S

Motor

IM

Earth

(Ground)

U

V

W

MC

REMARKS

To ensure safety, connect the power input to the inverter via a magnetic contactor and earth

leakage circuit breaker or no-fuse breaker, and use the magnetic contactor to switch power on-off.

The output is three-phase 200V.

1

.1.2 Layout and wiring of main circuit terminals

FR-S520-0.1K, 0.2K, 0.4K, 0.75K (-R) (-C)

FR-S520-1.5K, 2.2K, 3.7K (-R) (-C)
FR-S540-0.4K, 0.75K, 1.5K, 2.2K, 3.7K (-R)

P1

U

V

W

IM

R

S

T

N

P

Jumper

Power supply

Motor

P1

Jumper

R

S

T

U

V

W

IM

N

P

Power supply

Motor

FR-S520S-0.1K, 0.2K, 0.4K, 0.75K (-R)

FR-S520S-1.5K (-R)

P1

U

V

W

IM

N

P

R

S

Jumper

Power supply

Motor

P1

U

V

W

IM

N

P

R

S

Jumper

Power supply

Motor

FR-S510W-0.1K, 0.2K, 0.4K (-R)

FR-S510W-0.75K (-R)

U

V

W

IM

N

P

R

S

Power supply

Motor

U

V

W

IM

N

P

R

S

Power supply

Motor

CAUTION

The power supply cables must be connected to R, S, T. If they are connected to U, V, W,

the inverter will be damaged. (Phase sequence need not be matched.)

For use with a single-phase power supply, the power supply cables must be connected to
R and S.

Connect the motor to U, V, W.

Turning on the forward rotation switch (signal) at this time rotates the motor
counterclockwise when viewed from the load shaft.

Advertising
This manual is related to the following products: