118

2

.14.1

Communication settings

to

,

Communication-related parameters

Parameter

Name

Factory

Setting

<NA, EC

version>

Setting

Range

Remarks

Reflection

Timing

n1 (331)

Communication
station number

0

0 to 31

After reset

n2 (332)

Communication
speed

192

48, 96,

192

After reset

n3 (333) Stop bit length

1

0, 1, 10,

11

After reset

n4 (334)

Parity check
presence/
absence

2

0, 1, 2

After reset

n5 (335)

Number of
communication
retries

1

0 to 10,

- - -

Immediately

n6 (336)

Communication
check time
interval (*1)

0s

<- - ->

(*2)

0, 0.1 to

999s,

- - -

Immediately

n7 (337)

Wait time
setting

- - -

0 to 150ms,

- - -

After reset

n11 (341) CR/LF selection

1

0, 1, 2

Setting is enabled

when Pr. 30 = "1"

After reset

*1. To make communication, set any value other than 0 in the communication

parameter n6 "communication check time interval".

*2. Factory setting of NA and EC versions.

The parameter numbers within parentheses are those for use of the parameter unit
(FR-PU04).
Refer to page 177 for the instruction codes.

Communication specifications

Item

Computer

Conforming standard

RS-485 Standard

Number of inverters
connected

1:N (max. 32 inverters)

Communication speed

Selected between 19200, 9600 and 4800bps

Control protocol

Asynchronous

Communication method

Half-duplex

Character system

ASCII (7 bits/8 bits) selectable

Stop bit length

Selectable between 1 bit and 2 bits.

Terminator

CR/LF (presence/absence selectable)

Parity
check

Selectable between presence (even/odd) and absence

Communi

c

a

ti

on

s

pec

if

ic

at

ions

Check
system

Sumcheck

Presence

Waiting time setting

Selectable between presence and absence

Advertising
This manual is related to the following products: