PU contrast adjustment

By setting the communication parameter n15 "PU contrast adjustment", you can
adjust the LCD contact of the parameter unit (FR-PU04). When using the FR-

PU04, adjust the numerical value to any brightness with the

/

keys and

define that brightness with the

WRITE

key of the parameter unit.

Parameter

Name

Factory

Setting

Setting

Range

Remarks

n15 (991)

PU contrast adjustment

58

0 to 63

Setting is enabled when Pr. 30 = "1"

The parameter number in parentheses is the one for use of the parameter unit (FR-PU04).

CAUTION

When using the FR-PU04, you should press the

WRITE

key to store the LCD

contrast setting.

2

.15.4

PU main display screen data selection

You can choose the main display screen of the parameter unit (FR-PU04).

Parameter

Name

Factory

Setting

Setting

Range

Remarks

n16 (992)

PU main display
screen data
selection

0

0, 100

Setting is enabled when Pr. 30 = "1"

<Setting>

When you set 100 in n16, the monitor value changes depending on whether the
inverter is at a stop or running.

n16

0

100

During operation/stop

During stop

During operation

Output frequency

Output frequency

Set frequency

Output frequency

Output current

Output current

Alarm display

Alarm display

REMARKS

During an error, the output frequency at error occurrence appears.
During MRS, the values displayed are the same as during a stop.

Related parameters

Speed display

Pr. 37 "speed display" (refer to page 73)