Appendix 1 parameter data code list – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 186

Advertising
background image

177

APPENDIX 1 PARAMETER DATA CODE LIST

Data Code

Func-

tion

Parameter

Number

Name

Read Write

Computer

Link Data

Setting

Increments *

Link Parameter

Extension

Setting

(Data Code

7F/FF)

0

Torque boost

00

80

0.1%

0

1

Maximum frequency

01

81

0.01Hz

0

2

Minimum frequency

02

82

0.01Hz

0

3

Base frequency

03

83

0.01Hz

0

4

Multi-speed setting
(high speed)

04

84

0.01Hz

0

5

Multi-speed setting
(middle speed)

05

85

0.01Hz

0

6

Multi-speed setting
(low speed)

06

86

0.01Hz

0

7

Acceleration time

07

87

0.1s

0

8

Deceleration time

08

88

0.1s

0

9

Electronic thermal O/L
relay

09

89

0.01A

0

30

Extended function display
selection

1E

9E

1

0

Bas

ic

f

unct

ions

79

Operation mode selection

4F

None

1

0

The extended function parameters are made valid by setting "1" in Pr. 30 "extended
function display selection".

Data Code

Func-

tion

Parameter

Number

Name

Read Write

Computer

Link Data

Setting

Increments *

Link Parameter

Extension

Setting

(Data Code

7F/FF)

10

DC injection brake
operation frequency

0A

8A

0.01Hz

0

11

DC injection brake
operation time

0B

8B

0.1s

0

12

DC injection brake
voltage

0C

8C

0.1%

0

13

Starting frequency

0D

8D

0.01Hz

0

14

Load pattern selection

0E

8E

1

0

15

Jog frequency

0F

8F

0.01Hz

0

16

Jog acceleration/
deceleration time

10

90

0.1s

0

17

RUN key rotation
direction selection

11

91

1

0

19

Base frequency voltage

13

93

0.1V

0

20

Acceleration/deceleration
reference frequency

14

94

0.01Hz

0

21

Stall prevention function
selection

15

95

1

0

St

and

ar

d oper

at

io

n f

unc

ti

ons

22

Stall prevention operation
level

16

96

0.1%

0

Advertising