1 function (parameter) list – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 55

Advertising
background image

46

2

.1 Function (Parameter) List

Parameter

Indica-

tion

Name

Setting

Range

Minimum

Setting

Increments

Factory

Setting

<EC

version>

Refer

To:

Cus-

tomer

Setting

0

Torque boost

0 to 15%

0.1%

6%/5%/

4%

(Note 1)

58

1

Maximum frequency

0 to 120Hz

0.1Hz

60Hz

<50Hz>

59

2

Minimum frequency

0 to 120Hz

0.1Hz

0Hz

59

3

Base frequency

0 to 120Hz

0.1Hz

60Hz

<50Hz>

59

4 *

Multi-speed setting
(high speed)

0 to 120Hz

0.1Hz

60Hz

<50Hz>

61

5 *

Multi-speed setting
(middle speed)

0 to 120Hz

0.1Hz

30Hz

61

6 *

Multi-speed setting
(low speed)

0 to 120Hz

0.1Hz

10Hz

61

7

Acceleration time

0 to 999s

0.1s

5s

62

8

Deceleration time

0 to 999s

0.1s

5s

62

9

Electronic thermal O/L
relay

0 to 50A

0.1A

Rated
output
current

64

30 *

Extended function
display selection

0, 1

1

0

72

79

Operation mode
selection

0 to 4, 7, 8

1

0

98

Note 1: The factory setting varies with the inverter capacity: 5% for FR-S540-1.5K and

2.2K, 4% for FR-S540-3.7K.

The extended function parameters are made valid by setting "1" in Pr. 30 "extended
function display selection". (For full information on the way to set Pr. 30, refer to the
instruction manual (basic).)

Func-

tion

Pa-

rame-

ter

Indica-

tion

Name

Setting Range

Minimum

Setting

Increments

Factory

Setting

Refer

To:

Cus-

tomer

Setting

10

DC injection
brake
operation
frequency

0 to 120Hz

0.1Hz

3Hz

64

11

DC injection
brake
operation time

0 to 10s

0.1s

0.5s

64

12

DC injection
brake voltage

0 to 15%

0.1%

6%

64

13

Starting
frequency

0 to 60Hz

0.1Hz

0.5Hz

65

S

tanda

rd

op

e

ra

ti

o

n

fun

c

ti

o

n

s

14

Load pattern
selection

0: For constant-torque

loads,

1: For variable-torque

loads,

2: For vertical lift loads,
3: For vertical lift loads

1

0

66

Pammet

e

r Li

s

t

Advertising