Maximum and minimum frequency

You can clamp the upper and
lower limits of the output
frequency.

Output frequency (Hz)

Pr.1

Pr.2

Set frequency

5,10V

(20mA)

0

(4mA)

Parameter

Name

Factory Setting

<EC version>

Setting Range

1

Maximum frequency

60Hz <50Hz>

0 to 120Hz

2

Minimum frequency

0Hz

0 to 120Hz

<Setting>

Use Pr. 1 to set the upper limit of the output frequency. If the frequency of the
frequency command entered is higher than the setting, the output frequency is
clamped at the maximum frequency.

Use Pr. 2 to set the lower limit of the output frequency.

REMARKS

When using the potentiometer (frequency setting potentiometer) connected across
terminals 2-5 to perform operation above 60Hz <50Hz>, change the Pr. 1 and Pr. 38
(Pr. 39 when using the potentiometer across terminals 4-5) values.

CAUTION

When the Pr. 2 setting is higher than the Pr. 13 "starting frequency" value, note

that the motor will run at the set frequency by merely switching the start signal
on, without entering the command frequency.

Related parameters

Starting frequency setting

Pr. 13 "starting frequency" (refer to page 65)

Maximum frequency setting using external potentiometer

Pr. 30 "extended function display selection" (refer to page 72), Pr. 38 "frequency setting

voltage gain frequency", Pr. 39 "frequency setting current gain frequency" (refer to page 74)

2

.3.3

Base frequency, Base frequency voltage

Used to adjust the inverter
outputs (voltage, frequency) to
the motor rating.

Pr.19

Ou

tp

ut

v

o

lt

ag

e

Output

frequency (Hz)

Pr.3

Pr.47