65

2

Parameter

Name

Factory

Setting

Setting

Range

Remarks

10

DC injection brake
operation frequency

3Hz

0 to 120Hz

11

DC injection brake
operation time

0.5s

0 to 10s

12

DC injection brake voltage

6%

0 to 15%

Setting is enabled when
Pr. 30 = "1".

(When Pr. 11 is set to "0s" or Pr. 12 is set to "0%", DC injection brake is not operated.)

<Setting>

Use Pr. 10 to set the frequency at which the DC injection brake operation is started.
Use Pr. 11 to set the period during when the brake is operated.
Use Pr. 12 to set the percentage of the power supply voltage.
Change the Pr. 12. setting to 4% when using the inverter-dedicated (constant-torque
motor).
If the Pr. 12 value remains unchanged from the factory setting and Pr. 71 is changed
to the setting for use of the constant-torque motor, the Pr. 12 setting is automatically
changed to 4%.

CAUTION

Install a mechanical brake. No holding torque is provided.

2

.3.8

Starting frequency

The starting frequency at which
the start signal is turned on can
be set in the range 0 to 60Hz.

Output frequency

(Hz)

60

Pr.13

Frequency setting signal (V)

S

e

tt

in

g

r

ange

Foward rotation

ON

0

Time

Parameter

Name

Factory

Setting

Setting

Range

Remarks

13

Starting frequency

0.5Hz

0 to 60Hz Setting is enabled when Pr. 30 = "1".

CAUTION

The inverter will not start if the frequency setting signal is less than the value set in
Pr. 13 "starting frequency".
For example, when 5Hz is set in Pr. 13, the motor will not start running until the
frequency setting signal reaches 5Hz.

CAUTION

Note that when Pr. 13 is set to any value lower than Pr. 2 "minimum frequency",

simply turning on the start signal will run the motor at the preset frequency if the

command frequency is not input.

Related parameters

Minimum frequency setting

Pr. 2 "minimum frequency" (refer to page 59)