15 extended function display selection [p30, 16 frequency jump [p31] to [p36, 15 extended function display selection – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 81: 16 frequency jump to, Setting

Advertising
background image

72

2

.3.15

Extended function display selection

Used to display the extended function parameters.

Refer to page 46 for the extended function parameter list.
Refer to the instruction manual (basic) for the parameter setting method.

Parameter

Name

Factory

Setting

Setting

Range

Remarks

30

Extended function
display selection

0

0, 1

0: Without display,
1: With display

2

.3.16

Frequency jump

to

When it is desired to avoid
resonance attributable to the
natural frequency of a mechanical
system, these parameters allow
resonant frequencies to be
jumped. Up to three areas may be
set, with the jump frequencies set
to either the top or bottom point of
each area.

Pr.33

Pr.34

2B

2A

Pr.36
Pr.35

Pr.32
Pr.31

Frequency jump

3B

3A

1B

1A

R

u

nn

ing f

re

q

u

enc

y

(

H

z)

The value set to 1A, 2A or 3A is a jump point and operation is performed at this
frequency.

Parameter

Name

Factory

Setting

Setting Range

Remarks

31

Frequency jump 1A

- - -

0 to 120Hz, - - -

32

Frequency jump 1B

- - -

0 to 120Hz, - - -

33

Frequency jump 2A

- - -

0 to 120Hz, - - -

34

Frequency jump 2B

- - -

0 to 120Hz, - - -

35

Frequency jump 3A

- - -

0 to 120Hz, - - -

36

Frequency jump 3B

- - -

0 to 120Hz, - - -

- - -: Function invalid
Setting is enabled when
Pr. 30 = "1"

<Setting>

To fix the frequency at 30Hz between Pr. 33 and Pr. 34
(30Hz and 35Hz), set 30Hz in Pr. 33 and 35Hz in Pr. 34.

Pr.34:35Hz
Pr.33:30Hz

To jump to 35Hz between 30 and 35Hz, set 35Hz in
Pr. 33 and 30Hz in Pr. 34.

Pr.33:35Hz
Pr.34:30Hz

CAUTION

During acceleration/deceleration, the running frequency within the set area is valid.

REMARKS

Write inhibit error "

" occurs if the frequency jump setting ranges overlap.