8 additional function parameters, 1 remote setting function selection [p59, 1 remote setting function selection – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 95

Advertising
background image

86

2

.8 Additional Function Parameters

2

.8.1

Remote setting function selection

If the operator panel is located away from the control box, you can use contact
signals to perform continuous variable-speed operation, without using analog signals.

Deceleration(RM)
Clear(RL)

Acceleration(RH)

Forward rotation
(STF)

Out

p

u

t

fr

eq

u

enc

y (H

z)

ON

ON

Power supply

ON

*

ON

ON

ON

ON

ON

When Pr. 59="2"

When Pr. 59="1"

ON

ON

ON

* External operation frequency or PU operation frequency other than at multiple

speeds

Parameter

Name

Factory

Setting

Setting

Range

Remarks

59

Remote setting
function selection

0

0, 1, 2

Setting is enabled when Pr. 30 = "1"

REMARKS

When the remote function is used, the output frequency of the inverter can be

compensated for as follows:
External operation mode

Frequency set by RH/RM operation plus external
analog frequency command

PU operation mode

Frequency set by RH/RM operation plus setting dial
or PU digital preset frequency

<Operation panel operation procedure>

Monitor, frequency

setting mode

MODE

Press key to

complete setting.*

SET

Turn setting dial to

make correction.

* When you have set "1" in Pr. 53 "frequency setting operation selection", you

need not press the

SET

key.

Advertising