Electrical description, 1 power connector – Sony Ericsson TT4031 (SE-GM29) User Manual

Page 29

Advertising
background image

Owner’s Manual

Rev 1.0

Page 29 of 29

2. Electrical Description

All electrical connections to the TT4031 (SE-GM29) are designed to meet

the standard air (4 kV) and contact (8 kV) discharge ESD tests, of

EN 301 489-1.
The modem uses the following industry standard connectors:

RJ11 6-way (power connector)

RJ9 4-way (handset connector)

SIM card reader

FME male coaxial jack (antenna connector)

Sub-D socket, 9 pin (RS232 serial port)

2.1 Power Connector

An RJ11 6-way connector, as shown and described below, serves as a

means of supplying and controlling d.c. power to the modem.
The supply voltage, VCC, required by the modem is in the range 5 V - 32 V

d.c. Application of the supply voltage does not switch the modem on. To do

so an additional active-high control signal, TO_IN, must be applied for

> 0.2 s .
A second active-high control signal, HR_IN, can be used to switch the

modem off when applied for 1 - 2 seconds, or can be used to perform a

hardware reset when applied for > 3.5 s.
TO_IN and HR_IN are referenced to GND (pin 6 on the connector).
VCC and GND are reverse polarity and overvoltage protected