Power Supply

Supply voltage range

5 - 32 V d.c.

Power Consumption

Supply voltage

5V

12V

32V

Vdc

Power Down Mode

Av Max Av Max Av Max

5

15

5

15

20

50

µA

Standby Mode (typical)

Frequency Paging

rate Av Peak Av Peak Av Peak

900 MHz

2

26

110

9

43

6

20

mA

1800

MHz

2

26

120 9 45 6 19

mA

Talk Mode (typical)

Frequency Power

Level Av Peak Av Peak Av Peak

900 MHz

5

220 1230

90

520

40

200

mA

1900

MHz

0

170 960 70 350 30 140 mA

Note

! Power Down Mode: DC power is applied but the modem

is switched OFF.

Standby Mode: The TT4031 (SE-GM29) is switched ON and camped on to the

network. No call in progress.
Talk Mode: The TT4031 (SE-GM29) is switched ON and a voice/data call is in

progress.
The power consumption during transmission in Talk Mode is measured at

maximum transmitted power.
The power consumption in Standby Mode is measured at the maximum

paging rate.