Tektronix CSA8000B User Manual

Page 171

Advertising
background image

Measuring Waveforms

CSA8000B & TDS8000B User Manual

3- 97

Overview

Control elements and resources

To deskew between channels (cont.)

Set up the

reference

channel

5.

Set up the channel to be used as the reference channel:

a

Push the channel numbered button under Vertical
on the front panel.

b

Use the Vertical SCALE knob and POSITION
knobs to display the waveform edge to be
deskewed to fill the screen vertically.

6.

Use the Horizontal SCALE knob and POSITION knobs
to display the waveform edges to be deskewed to fill the
screen horizontally.

Deskew the

channel

7.

Set up the channel to be deskewed: repeat step 5 for
the channel to be deskewed.

8.

Push Vertical MENU front panel button, and from the
Vertical Setup dialog box, adjust the Deskew value (see
right) to make the edges of the reference and the
deskew channel coincide (or are as close as possible).

9.

If you cannot align the edges completely, try selecting
the reference channel and adjusting its deskew.

Deskew

more channels

10. If you need to, you can deskew additional channels:

11. Turn off the channel just deskewed, and leave the

reference channel on.

12. Set up the channel to be deskewed: repeat step 7 and

step 8 for the new channel to be deskewed.

13. Continue this process for as many channels as you want

to deskew.

14. Disconnect the deskew hookup.

End of Procedure