Creating Math Waveforms

CSA8000B & TDS8000B User Manual

3- 111

Overview

Related control elements & resources

To use math waveforms (cont.)

Take cursor

measurements

9.

Press the Vertical MATH button, and use the
numbered front-panel button to choose a math
waveform from M1 -- M8. The button will light amber
when you have chosen the waveform. (See figure at
upper right.)

10. Press the CURSORS button (see figure at lower

right). Press:

H Once to display vertical bar cursors (shown

below)

H A second time to display horizontal bar cursors
H A third time to display waveform-based cursors

11. Press the SELECT button to toggle selection

between the two cursors.

12. Turn the knob to position each cursor on the math

waveform to measure the feature that interests you.

13. Read the results in cursor readout.

In the figure shown above, waveform cursors are
used to measure the V of the integral math
waveform, which could be used to compute its
area (

svdt).

End of Procedure

For more information on taking automatic and cursor measurements of wave-
forms, see Measuring Waveforms on page 3--73.