5.RAS Functions

132

PROSEC T2N

(4) Sequence time over detection function

The alarm step is provided for one of SFC (sequential function chart)

instructions. This Alarm step turns ON the specified device when the

following transition is not come true within the preset time from the start of

the step.

This function allows easy detection of operation holds up in sequential

control process.

With the above example, if the transport has not been completed (work

arrived signal ON etc) within 10 seconds, the specified alarm device (R1000)

comes ON. By this means a malfunction generated by the work drive or

the sensor can be detected.

Refer to Part 3 of this manual and the other instruction set manual for

explanation with respect to SFC.

(SFC structure)

(action part)

(transition conditions)

A

Processing

completed

Transport

completed

work

work transport

Alarm step

monitor timer = T003

monitor time = 10 seconds

alarm device = R1000

120

121
T003

1000

R1000