4. I/O Allocation

196

PROSEC T2N

Input/output allocation information can be freely edited and registered
by carrying out manual I/O allocation. However, it is necessary that
the registered input/output allocation information and the I/O module
mounting state should agree for starting-up RUN.
When executing the ‘forced run’command, operation (RUN-F mode)
is possible even if the modules registered in the allocation information
are not in the mounted state. However, in this case also, operation
cannot be executed when a module of a different type to the
registered module is mounted (I/O mismatch).

In manual I/O allocation, the starting register address (input/output
registers) of each unit can be set and registered.

The register addresses can be arranged for every unit by using this function.
Also, when an I/O module is added in a vacant slot in the future, it is
possible to avoid affecting the register addresses of other units.

(Unit Starting Address Setting/Display Screenon T-PDS)

Unit #0

Unit #1

Unit #2

Unit #3

Top Register No.

Top Register No.

Top Register No.

Top Register No.

[

0

]

[

15

]

[

35

]

[

50

]

In the case of this screen example, address allocations can be carried
out

from XW/YW000 for the basic unit
from XW/YW015 for expansion unit #1
from XW/YW035 for expansion unit #2
from XW/YW050 for expansion unit #3.

Settings by which latter stage units become lower register addresses
cannot be made.