Toshiba VF-nC1 User Manual

Page 100

Advertising
background image

E6581090

H-3

8

8.2

Display of trip information

If the inverter trips, an error code is displayed to suggest the cause. In the status monitor mode, all
trip records are retained.

Display of trip information

Error code

Communication No. Description

PGTT

(*)

0000

No error

QE

0001

Overcurrent during acceleration

QE

0002

Overcurrent during deceleration

QE

0003

Overcurrent during operation

QEN

0004

Load-side overcurrent during start-up

QEC

0005

Armature-side overcurrent during start-up

GRJ

0008

Input phase failure

GRJQ

0009

Output phase failure

QR

000A

Overvoltage during acceleration

QR

000B

Overvoltage during deceleration

QR

000C

Overvoltage during constant-speed operation

QN

000D

Inverter overload trip

QN

000E

Motor overload trip

QJ

0010

Overheat trip

G

0011

Emergency stop

GGR

0012

E2PROM fault 1

GGR

0013

E2PROM fault 2

GGR

0014

E2PROM fault 3

GTT

0015

Inverter RAM fault

GTT

0016

Inverter ROM fault

GTT

0017

CPU fault trip

GTT

0018

Communication error

GTT

001A

Current detector fault

WR

001E

Undervoltage trip

GH

0022

Ground fault

QER

0025

Overcurrent flowing in element during acceleration

QER

0026

Overcurrent flowing in element during deceleration

QER

0027

Overcurrent flowing in element during low-speed operation

G

0032

Trip caused by a break in an analog signal cable

G

0033

CPU communication error

G

0034

Excessive torque boosted

(Note) Past trip records (trip records retained or trips that occurred in the past) can be called up.

(Refer to 8.1 "Status monitor mode" for the call-up procedure.)
(*) Strictly speaking, this code is not an error code; this code is displayed to show the

absence of error when the past trip monitor mode is selected.

Advertising