Toshiba VF-nC1 User Manual

Page 14

Advertising
background image

E6581090

A-5

1

Note: The self-up (self-lifting) terminals of VFNC1 are constructed with plastic body and screws,

therefore please take following precautions.
• Do not unscrew the power terminals to UP position frequently. (Less than 5 times is

recommended)

• Do not press the screw when unscrew the main terminals.
• Do not unscrew quickly like using an Electric screw driver.
• Do not pull the power wire during unscrewing the power terminals to UP position.
• Do not unscrew the power terminal to UP position with over torque.
• Do not make any deformation of the cover when unscrewing the power terminals.

1.3.2 Main circuit and control circuit terminal blocks

1) Main circuit terminal block

When using a crimp terminal, cover its caulked part with a tube or use an insulated terminal.

Screw size

tightening torque

M3 screw

0.8N ・ m

M3.5 screw

1.0N ・ m

[Main circuit input terminals]

[Main circuit output terminals]

VFNC1-2001P~2007P

Advertising