Toshiba VF-nC1 User Manual

Page 106

Advertising
background image

E6581090

I-4

9

(6) Installation of the zero-phase and/or the ferrite core can also effectively reduce the radiated

noise further. (Input or/and output of inverter)

Ex. Countermeasure - main circuit wiring

Fig. 2

Note 1)
Process as shown below.

Shielded cable

Fig. 3

Operating with external signals

To operate with external signals, process as following figures.

Fig. 4

IM

Inverter panel
(Metal)

Separate input and
output cables.
Do not run input
cables along-side
output cables.
Do not bundle input
and output cables.

Shielded cables

Connect to the
power source

Connect to
the control

Grounding plate

EMI filter

Strip the coating of the cable and fix the shielded part
to the metal plate using a metal fitting.

P5

VI/S3

CC

F
R

Control
circuit
terminal

Ferrite core 1

Shielded cable

Potentiometer

Forward
Reverse

NOTE1)