Toshiba VF-nC1 User Manual

Page 99

Advertising
background image

E6581090

H-2

8

(Continued)

Item

displayed

Key

operated

LED

display

Communication

No.

Description

CPU1

version

X

FE08

The version of the CPU1 is displayed.

CPU2

version

XY

FE73

The version of the CPU2 is displayed.

Memory

version

XG

FE09

The version of the memory mounted is displayed.

Past trip 1

QE ⇔

FE10

Past trip 1 (displayed alternately at 0.5-sec. intervals)

Past trip 2

QJ  ⇔

FE11

Past trip 2 (displayed alternately at 0.5-sec. intervals)

Past trip 3

QR ⇔

FE12

Past trip 3 (displayed alternately at 0.5-sec. intervals)

Past trip 4

PGTT

⇔

FE13

Past trip 4 (displayed alternately at 0.5-sec. intervals)

Cumulative

operation

time

VQ

FE14

The cumulative operation time is displayed.
(0.01 corresponds to 1 hours.)

Default
display

mode



The operation frequency is displayed (during operation).

Note 1: Press the or key to change items displayed in the status monitor mode.

Note 2: With the current unit selection parameter or voltage unit selection parameter, you can choose

between percentage and ampere (A) for current or between percentage and volt (V) for
voltage, respectively.

Note 3: The input (DC) voltage displayed is 1/

2

times as large as the rectified d.c. input voltage.

Note 4: PGTT is displayed to show the absence of error.
Note 5: The cumulative operation time increments only when the machine is in operation.

Note 5

Note 4

Note 4

Note 4

Note 4

MON

Advertising