E6581090

F-13

6

Reduction in rated load current

When the PWM carrier frequency is set above 4kHz, the rated current needs to be decreased.

Carrier frequency

VFNC1S-
VFNC1-

Ambient
temperature

4kHz or less

8kHz

12kHz

16kHz

2001P

50°C or less

0.7A

0.7A

0.7A

0.7A

2002P

50°C or less

1.4A

1.4A

1.4A

1.4A

40°C or less

2.4A

2.4A

2.4A

2.4A

2004P

40 to 50°C

2.4A

2.4A

2.4A

2.2A

40°C or less

4A

4A

3.6A

3A

2007P

40 to 50°C

4A

3.6A

3.2A

2.8A

40°C or less

7.5A

7.5A

7.5A

7.1A

2015P

40 to 50°C

7.5A

7.5A

7.1A

6.3A

40°C or less

10.0A

9.5A

8.5A

7.5A

2022P

40 to 50°C

10.0A

8.5A

7.5A

6.5A

1001P

50°C or less

0.7A

0.7A

0.7A

0.7A

1002P

50°C or less

1.4A

1.4A

1.4A

1.4A

40°C or less

2.4A

2.4A

2.4A

2.4A

1004P

40 to 50°C

2.4A

2.4A

2.4A

2.2A

1007P

50°C or less

4A

4A

4A

4A

40°C or less

1.2A

1.2A

1.2A

1.2A

2002PL

40 to 50°C

1.1A

1.1A

1.1A

1.1A

40°C or less

2.3A

2.3A

2.3A

2.3A

2004PL

40 to 50°C

2.1A

2.1A

2.1A

2.1A

40°C or less

4A

3.6A

3.2A

2.8A

2007PL

40 to 50°C

3.6A

3.2A

2.9A

2.5A

40°C or less

7.5A

7.5A

7.5A

7.1A

2015PL

40 to 50°C

6.8A

6.8A

6.8A

6.4A

40°C or less

10.7A

10.1A

9.1A

8A

2022PL

40 to 50°C

9.6A

9.1A

8.2A

7.2A

Function

Although the rated current at 4kHz is shown on the rating plate, the PWM carrier frequency is
set to 12kHz by default.

Note: In order to protect the inverter, PWM carrier frequency may fall automatically depending on

the circumstances even if it is under the derating in accordance with above table.
If using foot-mounted type noise reduction filter EMFAS2011Z or EMFA2006Z with VF-nC1, it
is necessary to decrease 5% more of rated current in above table.

6.10

Trip-less intensification

6.10.1 Auto-restart (restart during coasting)

H : Auto-restart control selection

Caution

Mandatory

• Stand clear of motors and mechanical equipment.

If the motor stops because of a momentary power failure, the equipment will start suddenly
when the power is restored, and could cause injury.

• To prevent accidents, attach labels warning that there is the risk of a sudden start in the event

of a power failure to all inverters, motors and machines.

Function

This parameter detects the rotational speed and direction of rotation of the motor during coasting in the
event of a momentary power failure, and restarts the motor smoothly as soon as power is restored (motor
speed search function). Also, this parameter makes it possible to switch from commercial power operation to
inverter operation without stopping the motor.

During restart operation, the message “

TVT[

” is displayed.