Toshiba VF-nC1 User Manual

Page 75

Advertising
background image

E6581090

F-11

6

6.6

DC braking

6.6.1 DC braking

H : DC braking starting frequency (Hz)
H : DC braking current (%)
H : DC braking time (s)

Function

Large braking torque can be obtained by applying a direct current to the motor. These
parameters are used to set the direct current to be applied to the motor, the application time
and the starting frequency.

[Parameter setting]

Title

Function

Adjustment range

Default setting

H

DC braking starting frequency
(Hz)

0.0:(OFF),
0.1~HJ(Hz)

0.0

H

DC braking current (%)

0~100(%)

50.0

H

DC braking time (s)

0.0:(OFF)
0.1~20.0(sec)

1.0

Time [sec]

DC braking starting
frequency H

DC braking current H

DC braking time H

Output frequency [Hz]

DC braking stop

Operation signal [F-CC]

ON
OFF

Output current [A]

0

0

Set frequency

Note: During DC braking, the overload protection sensitivity of the motor increases. To prevent

tripping, the DC braking current is adjusted automatically in some cases.