Toshiba VF-nC1 User Manual

Page 126

Advertising
background image

E6581090

L-2

12

Item

Specification

Input voltage

1-phase 100V

Applicable motor (kW)

0.1

0.2

0.4

0.75

1.5

2.2

Type

VFNC1S

Form

1001P

1002P

1004P

1007P

-

-

Capacity (kVA) Note 1)

0.3

0.6

1.0

1.6

-

-

Rated output current (A)

Note 2)

0.7

1.4

2.4

4.0

-

-

Rated output voltage

Note 3)

3-phase 200V to 230V

Ra

tin

g

Overload current rating

60 seconds at 150%, (50%-reduction value)

Voltage-frequency

1-phase 100V to 115V - 50/60Hz

Allowable fluctuation

Voltage +10%, -15% Note 4), frequency ±5%

Po

w

er

su

pp

ly

Ampere Interrupt
Capacity (A) AIC

1000

1000

1000

1000

-

-

Protective method

IP20 Enclosed type (JEM 1030)

Cooling method

Self-cooling

Forced

air-cooled

-

-

Color

Munsel 5Y8/0.5

Charge lamp

LED indicating the charge status of the capacitor in the main circuit

Built-in filter

-

Item

Specification

Input voltage

1-phase 200V (built-in EM1 noise filter)

Applicable motor (kW)

0.1

0.2

0.4

0.75

1.5

2.2

Type

VFNC1S

Form

-

2002PL

2004PL

2007PL

2015PL

2022PL

Capacity (kVA) Note 1)

-

0.5

0.9

1.6

2.9

4.1

Rated output current (A)

Note 2)

-

1.2

2.3

4.0

7.5

10.7

Rated output voltage

Note 3)

3-phase 200V to 240V

Ra

tin

g

Overload current rating

60 seconds at 150%, (50%-reduction value)

Voltage-frequency

1-phase 200V to 240V - 50/60Hz

Allowable fluctuation

Voltage +10%, -15% Note 4), frequency ±5%

Po

w

er

su

pp

ly

Ampere Interrupt
Capacity (A) AIC

-

1000

1000

1000

5000

5000

Protective method

IP20 Enclosed type (JEM 1030)

Cooling method

-

Self-cooling

Forced air-cooled

Color

Munsel 5Y8/0.5

Charge lamp

None

Built-in filter

EMC noise filter (Class B)

Note)

1. Capacity is calculated at 220V for the 200V models.
2. Indicates rated output current setting when the PWM carrier frequency (parameter H) is 4kHz or

less.
If the PWM carrier frequency setting is fixed above 4 kHz, the rated current needs to be reduced. If the
PWM carrier frequency is set above 4 kHz, it could fall automatically if an over-current flaws during
acceleration or for any other reason, depending on the amount of current that flows.
The default setting of the PWN carrier frequency is 12kHz.

3. Maximum output voltage is the same as the input voltage.

With regard to 100V models, the output voltage may decrease about 10 to 20 % if motor load is applied.
When operating VFNC1 in conjunction with general purpose motor (200V), it is necessary to reduce the
motor load.

4.

±10% when the inverter is used continuously (load of 100%).