E6581090

B-5

2

Main circuit

R/L1

S/L2

T/L3

P0 PA PC

DC reactor
(DCL: option)

U/T1

V/T2

W/T3

IM

VF-nC1

FLC

FLB

FLA

P5

VI/S3*2 *3

CC

F

R

S1

S2

P15

FM/OUT*2

CC

Meter

Connector for

optional devices

Forward

Preset speed 2

Reverse

Preset speed 1

Common

Fault output signal

External potentiometer
(3-10kΩ)
or input voltage signal
(0-10Vdc)

Current signal
4-20mAdc

Frequency meter
(Ammeter)

Control circuit

MCCB

1

Ry

5

4

1-phase series

Power
supply

R/L1

S/L2

1-phase series do not have T/L3 terminal.

MCCB

2.2.2 Standard connection diagram (2)

(2) Source <common: P15>

When using V1/S3 terminal as an analog input terminal (H :  or )

*1: Only European model has a built-in noise filter.
*2: The terminal can be switched between FM/OUT and VI/S3 by changing a

parameter.

*3: The terminal can also be used as an input terminal by changing a parameter.
*4: European models are not provided with PO terminal.
*5: 1-phase 100V models cannot be used with DC reactors.