Toshiba VF-nC1 User Manual

Page 115

Advertising
background image

E6581090

K-3

11

11.3

Extended parameters

 

Input/output parameters

Title

Communication

No.

Function

Unit

Minimum setting

unit Panel/

Communication

Adjustment range

Default

setting

User

setting

Reference

H

0100

Low speed signal
output frequency

Hz

0.1/0.01

0.6-HJ

0.6

6.1.1

H

0101

Speed-reach setting
frequency

Hz

0.1/0.01

0.0-HJ

0.0

6.1.2

H

0109

Analog input/logic
input function
selection (VI/S3)

-

-

0:Voltage signal input

(0-5 or 10V)

1:Current signal input

(4-20mA)

2:Contact input

0

6.2.1

H

0110

Always active
function selection

-

-

0~40, 49, 54~57

1

(ST)

6.2.2

H

0111

Input terminal
selection 1 (F)

-

-

0~40, 49, 54~57

2

(F)

6.2.3

H

0112

Input terminal
selection 2 (R)

-

-

0~40, 49, 54~57

3

(R)

6.2.3

H

0113

Input terminal
selection 3 (S1)

-

-

0~40, 49, 54~57

6

(SS1)

6.2.3

H

0114

Input terminal
selection 4 (S2)

-

-

0~40, 49, 54~57

7

(SS2)

6.2.3

H

0115

Input terminal
selection 5 (VI/S3)*5

-

-

5-17

8

(SS3)

6.2.3

H

0127

Sink/Source selection

-

-

0: Sink 100: Source
1-99,101-200: Disabled

*2

6.2.5

H

0130

Output terminal
selection 1
(FM/OUT)*6

-

-

0-13

4

(LOW)

6.2.6

H

0132

Output terminal
selection 3 (FL)

-

-

0-13

10

(FL)

6.2.6

H

0170

Base frequency 2

Hz

0.1/0.01

25-200

*2

6.3.1

H

0171

Base frequency
voltage 2

V

1/1

50-500

*2

6.3.1

H

0172

Torque boost 2

%

0.1/0.1

0.0-30.0

*3

6.3.1

H

0173

Motor thermal
protection level 2

%

1/1

30-100

100

6.3.1

*2: The value is changed according to the set-up parameter condition.

(VFNC1 (S)-□□□□P□-W type)
FH:80, UL80, VL:60, F127:0, F170:60, F171:200, F204:80, F409:200, F417:1710 for VFNC1 (S)-□□□

P□ type.

*3: Parameter values vary depending on the capacity. Refer to page K-8.
*5: This function is enabled if F109 is set at 2 (logic input).
*6: This function is enabled if FMSL (open collector output) is set at 1.