E6581090

M-2

13

(Continued)

Error
code

Alarm

code

Problem

Possible causes

Remedies

QR

000B

Overvoltage during
deceleration

• The deceleration time FGE is

too short. (Regenerative
energy is too large.)

• H (overvoltage limit

operation) is off.

• The input voltage fluctuates

abnormally.

The power supply has a
capacity of 200kVA or more.

A power factor improvement
capacitor is opened or closed.

A system using a thyristor is
connected to the same power
distribution line.

• Increase the deceleration time

FGE

.

• Enable H (overvoltage

limit operation).

• Insert a suitable input reactor.

QR

000C

Overvoltage during
constant-speed
operation

• The input voltage fluctuates

abnormally.

The power supply has a
capacity of 200kVA or more.

A power factor improvement
capacitor is opened or closed.

A system using a thyristor is
connected to the same power
distribution line.

• The motor is in a regenerative

state because the load causes
the motor to run at a frequency
higher than the inverter output
frequency.

• Insert a suitable input reactor.

QN

000D

Inverter overload

• The acceleration time ACC is

too short.

• The DC braking amount is too

large.

• The V/F setting is improper.
• A restart signal is input to the

rotating motor after a
momentary stop, etc.

• The load is too large.

• Increase the acceleration time

CEE

.

• Reduce the DC braking amount

H

and the DC braking

time H.

• Check the V/F parameter

setting.

• Use H (auto-restart) and

H
(ride-through control).

• Use an inverter with a larger

rating.

QN

000E

Motor overload

• The V/F setting is improper.
• The motor is locked up.

• Low-speed operation is

performed continuously.

• An excessive load is applied to

the motor during operation.

• Check the V/F parameter

setting.

• Check the load (operated

machine).

• Adjust QNO to the overload

that the motor can withstand
during operation in a low speed
range.

*
GRJ

0009

Output phase failure

• A phase failure occurred in the

output line of the main circuit.

• Check the main circuit output

line, motor, etc., for phase
failure.

• Enable H (Output phase

failure detection).

(Continued overleaf)