Basic vf-nc1 operations – Toshiba VF-nC1 User Manual

Page 42

Advertising
background image

E6581090

D-1

4

4. Basic VF-nC1 operations

The VF-nC1 has the following three monitor modes.

Standard monitor mode

: The standard inverter mode. This mode is enabled when

inverter power goes on.

Setting monitor mode

:

The mode for setting inverter parameters.

For more on how to set parameters, see 4.1.

 

Status monitor mode

:

The mode for monitoring all inverter status.

Allows monitoring of set frequencies, output current/voltage and

terminal information.

For more on how to use the monitor, see 8.1.

Pressing the MON key will move the inverter through each of the modes.

Standard monitor mode

Status monitor mode

Setting monitor mode

MON

MON

MON

After mode is for monitoring the output frequency and setting the frequency
designated value by UP/DOWN key of operation panel. In it is also displayed
information about status alarms during running and trips.

• Setting frequency designated values - see 3.1.2
• Status alarm

If there is an error in the inverter, the alarm signal and the frequency will flash
alternately in the LED display.

E

: When a current flows at or higher than the overcurrent stall level.

R

: When a voltage is generated at or higher than the over voltage stall

level.

N

: When a load reaches 50% or higher of the overload trip value.

J

: When temperature inside the inverter rises to the overheating protection

alarm level.
All VF-nC1 series of inverters: About 110°C