11

Table of input terminal functions 2

Function

No.

Code

Function

Action

29

R+SS4

Combination of reverse run and preset
speed command 4

ON : Simultaneous input of R and SS4

commands

30

F+SS1+AD2

Combination of forward run, preset
speed command 1 and
acceleration/deceleration 2

ON : Simultaneous input of F, SS1 and

AD2 commands

31

R+SS1+AD2

Combination of reverse run, preset
speed command 1 and
acceleration/deceleration 2

ON : Simultaneous input of R, SS1 and

AD2 commands

32

F+SS2+AD2

Combination of forward run, preset
speed command 2 and
acceleration/deceleration 2

ON : Simultaneous input of F, SS2 and

AD2 commands

33

R+SS2+AD2

Combination of reverse run, preset
speed command 2 and
acceleration/deceleration 2

ON : Simultaneous input of R, SS2 and

AD2 commands

34

F+SS3+AD2

Combination of forward run, preset
speed command 3 and
acceleration/deceleration 2

ON : Simultaneous input of F, SS3 and

AD2 commands

35

R+SS3+AD2

Combination of reverse run, preset
speed command 3 and
acceleration/deceleration 2

ON : Simultaneous input of R, SS3 and

AD2 commands

36

F+SS4+AD2

Combination of forward run, preset
speed command 4 and
acceleration/deceleration 2

ON : Simultaneous input of F, SS4 and

AD2 commands

37

R+SS4+AD2

Combination of reverse run, preset
speed command 4 and
acceleration/deceleration 2

ON : Simultaneous input of R, SS4 and

AD2 commands

38

FCHG

Frequency command forced switching

Enabled if HOQF = 4 (selectable
between terminal board and operation
panel/internal potentiometer)
ON : VI terminal
OFF : Internal potentiometer

39

THR2

No.2 thermal switching

ON : No.2 thermal (RV:, H,

H

, H, H)

OFF : No.1 thermal (RV: Setting, XN,

H

, XD, VJT)

40

MCHG

No.2 motor switching

ON : No.2 motor (RV:0, H,

H

, H, H, H,

H

)

OFF : No.1 motor (Pt: Setting, XN,

H

, XD, VJT, CEE,

FGE

)

49

HD

Operation holding
(Stop of 3-wire operation)

ON : F (forward run) / R (reverse run)

held, 3-wire operation

OFF : Slowdown stop

54

FreeRun

Standby (inversion)

ON : Free run
OFF : Standby

55

RSTN

Reset signal (inversion)

OFF to ON: Trip reset

56

F+ST

Combination of forward run and standby
commands

ON : Simultaneous input of F and ST

commands

57

R+ST

Combination of reverse run and standby
commands

ON : Simultaneous input of R and ST

commands

*This function is effective after software version V110.

*