Chapter 2 – Yamaha SU700 User Manual

Page 53

Advertising
background image

Chapter 2 Tutorial

53

CHAPTER

2

Press twice

NOTE:
On LOOP tracks, stereo samples may sometimes produce an inappropriate click at the
loop ends. You can avoid this problem by using monaural recording for these tracks. Al-
ternatively, you can record these as stereo samples and then convert to monaural later,
if necessary, using the SAMPLE | PROCESS

SAMPLE TO MONO

job (

p.270).

To adjust, press the right arrow button

twice to select the format parameter, so

that the parameter is blinking on the screen. Then turn the dial to select

MONO L

.

7.

Now let’s adjust the input level from the CD. First, start playback of track 79 on the
sampling CD.
▼ If the CD player is correctly connected to the SU700, you will hear the sound com-

ing through the SU700 and you will see the level meter moving on the screen. Note
that the meter grows to the right as the level increases; and that the word

CLIP

ap-

pears if the level goes too high.

(The upper horizontal bar indicates the input to the right-channel level. The
lower bar indicates the input to the left-channel level. For monaural record-
ing, both bars move together.)

Turn the ANALOG LEVEL dial to adjust the level. You want to adjust so that peak
levels bring the meter reading all the way to the right

without triggering the CLIP

warning.

Appears if level

goes too high.

Meter grows this way to indicate rising level.

Lch
Rch

Advertising