GE Industrial Solutions AF-300 MICRO-$AVER II User Manual

Page 32

Advertising
background image

5-4

Not effective

Not effective

Not effective

Not effective

Not effective

RUN Mode

m/min display

Keypad panel

operation:

Drive will stop

Display = A

Terminal operation:

F_02=1 Drive will stop

LED will show Er6

F_02=2 Stop key not

operational

Keypad panel

operation:

Drive will stop

Display = V

Terminal operation:

F_02=1 Drive will stop

LED will show Er6

F_02=2 Stop key not

operational

Keypad panel

operation:

Drive will stop

Display = r/min

Terminal operation:

F_02=1 Drive will stop

LED will show Er6

F_02=2 Stop key not

operational

Keypad panel

operation:

Drive will stop

Display = m/min

Terminal operation:

F_02=1 Drive will stop

LED will show Er6

F_02=2 Stop key not

operational

Keypad panel

operation:

Drive will stop

Display = Hz

Terminal operation:

F_02=1 Drive will stop

LED will show Er6

F_02=2 Stop key not

operational

Hz display

A display

V display

r/min display

FUNC
DATA

FUNC
DATA

FUNC
DATA

FUNC
DATA

RUN

RUN

RUN

RUN

RUN

STOP

STOP

STOP

STOP

STOP

* NOTE: See TABLE 6 (page 5-12) for Functions that can be changed while in RUN Mode.

PROGRAM Mode

while running

PRG
Reset

PRG
Reset

PROGRAM Mode

while running

PROGRAM Mode

while running

PROGRAM Mode

while running

PROGRAM Mode

while running

PRG
Reset

PRG
Reset

PRG
Reset

*

Advertising