GE Industrial Solutions AF-300 MICRO-$AVER II User Manual

Page 43

Advertising
background image

6-4

LED

Data

Factory

Customer

Display

Setting

Description

Setting

Setting

F_05

80

MAXIMUM OUTPUT VOLTAGE

230

to

This sets the maximum output voltage for the

230/240

Drive in steps of 1V (230V/240V

) and 2V (480V).

160
to
480

460

NOTE: The output voltage cannot be higher than the
voltage input from the power supply.

*F_06

ACCELERATION TIME 1

6.0

*F_07

DECELERATION TIME 1

6.0

0.01

The time from start to maximum frequency

to

(acceleration) and from maximum frequency to stop

3600

(deceleration) can be set within the range of 0.01
to 3600 seconds. Set values according to the load
characteristics for Wk

2

.

*F_ 08

TORQUE BOOST 1

2

Torque boost can be set to optimize the V/Hz
characteristics of the Drive according to the type of
load the motor will see. Set only high enough to
develop sufficient low frequency torque; too high of a
value will cause diminished performance and
excessive motor heating.

0

Torque boost is automatically controlled.

1

Squared torque characteristics
(for fans and pumps)

2

Proportional torque characteristics

3

(Weak)

31

(Strong)

240V is for single phase input only.

Setting Range

Setting Step

0.00* to 9.99s

0.01s

10.0 to 99.9s

0.1s

* When set to 0.00

100 to 999s

1s

the time becomes

1,000 to 3,600s

10s

0.01 seconds.