6-10

LED

Data

Factory

Customer

Display

Setting

Description

Setting

Setting

*F_21

MULTISTEP FREQUENCY #1

5.00Hz

*F_22

MULTISTEP FREQUENCY #2

10.00Hz

*F_23

MULTISTEP FREQUENCY #3

20.00Hz

*F_24

MULTISTEP FREQUENCY #4

30.00Hz

*F_25

MULTISTEP FREQUENCY #5

40.00Hz

*F_26

MULTISTEP FREQUENCY #6

50.00Hz

*F_27

MULTISTEP FREQUENCY #7

60.00Hz

These Functions set the frequency for multistep
frequency operation. The frequencies are selected as
shown in the table below by setting control terminals
X1-CM, X2-CM and X3-CM to ON/CLOSED.

[Relationship between terminals and multistep
frequencies 1-7]

= ON/CLOSED

(1) Speed 0 (when X1-CM, X2-CM and X3-CM are all
OFF/OPEN) depends on the frequency setting method
selected by means of function F_01. In other words, the
setting becomes digital (using the and keys) or
analog ([0 to 10VDC] or [4 to 20mA VDC]).
(2) The actual operation frequency is limited by the maximum
frequency F_03 and the frequency limiters F_36 and F_37.

Function

1

21

22

23

24

25

26

27

Multistep

Speed Speed Speed Speed Speed Speed Speed Speed

Frequency

0

1

2

3

4

5

6

7

X1 – CM

X2 – CM

X3 – CM

Advertising