GE Industrial Solutions AF-300 MICRO-$AVER II User Manual

Page 46

Advertising
background image

LED

Data

Factory

Customer

Display

Setting

Description

Setting

Setting

6-7

Drive frequency (Hz)

Drive frequency (Hz)

F_15

ELECTRONIC OVERLOAD 1

1

The Drive's Electronic Overload can be selected to
help protect the motor from thermal overload due to
various operating conditions. Selection should be
based on operating conditions, type of load, motor
thermal characteristics, applicable NEC and
local electrical code requirements.
The motor thermal characteristics and the diagram
shown in Function Code 16 should be reviewed.
Their characteristics should be coordinated to determine
what is the protection level available with the Drive/motor
combination, and what additional protection will be
required (Refer to Function Code 16).

0

Inactive (External motor thermal overload device)

1

Active (Review motor thermal characteristics)

2

Special factory setting for forced air cooled motor.
(Consult Motor Manufacturer)

1) For a standard 4-pole motor

1

2) For a special design motor

2