GE Industrial Solutions AF-300 MICRO-$AVER II User Manual

Page 48

Advertising
background image

LED

Data

Factory

Customer

Display

Setting

Description

Setting

Setting

6-9

F_17

DC BRAKE (Operation Selection)
This selects the DC brake operation to active or inactive

0

0:

Inactive - (Regenerative braking only)

1:

Active - (DC braking after regenerative braking)

*F_18

0 to 60

DC BRAKE (Starting Frequency)
Sets the frequency to start DC injection brake

0 Hz

operation during deceleration.

*F_19

0 to 100

DC BRAKE (Brake Level)
Sets the output braking level (brake output) for the DC

50%

injection brake. The braking strength will
vary depending on the characteristics of the motor.

*F_20

0.00 to 30

DC BRAKE (Braking Time)
Sets the operation time for the DC injection brake.

0.5s

1

If the data is set to "0", the frequency will be 0.2 Hz.

The Drive braking function cannot be substituted
for mechanical means. Attempting to do so may
result in injury.

Starting Range

Unit

Setting Step

Starting Frequency

0

1

to 60

Hz

1 Hz

Braking Level

0 to 100

%

1%

Braking Time

s

0.00 to 9.99
10.0 to 30.0

0.01
0.1

Operating

Speed

Operating

Speed

Time

Time