LED

Data

Factory

Customer

Display

Setting

Description

Setting

Setting

6-17

F_43

X4 TERMINAL FUNCTION

0

The function for the X4 input terminal can be selected from
the following four options.

0:

Functions as a command input terminal X4 for
switching to acceleration/deceleration time 2.
The acceleration time 2 and deceleration time 2 are set
by F_63 and F_64.

1:

Enables the use of multistep frequency settings 8 to 15.
Frequencies 8 to 15 are set by means of F_44 to F_51.

2:

Functions as a command terminal X4 for switching
to base frequency 2 when using a second motor, etc.
When base frequency 2 is selected, acceleration/
deceleration time 2, torque boost 2 and electronic
overload 2 are selected simultaneously.
Base frequency 2 is set using function F_62, acceleration/
deceleration time 2 are set by function F_63 and F_64,
torque boost 2 is set by function F_65, and electronic
overload 2 is set by F_66 and F_67.

3:

Functions as a hold signal (HLD) for operation commands
during 3-wire control operation.

*F_44

MULTISTEP FREQUENCY SETTING 8

0.00

*F_45

MULTISTEP FREQUENCY SETTING 9

0.00

*F_46

MULTISTEP FREQUENCY SETTING 10

0.00

*F_47

0 to 400

MULTISTEP FREQUENCY SETTING 11

0.00

*F_48

MULTISTEP FREQUENCY SETTING 12

0.00

*F_49

MULTISTEP FREQUENCY SETTING 13

0.00

*F_50

MULTISTEP FREQUENCY SETTING 14

0.00

*F_51

MULTISTEP FREQUENCY SETTING 15

0.00

These set the 8 multistep frequencies from frequency 8 to
frequency 15 within the range of 0 to 400Hz.
The setting step is the same as for functions F_21 through
F_27.
(Relationship between terminals and multistep frequencies
8 through 15)

= ON/CLOSED.

NOTE: These functions are only active when F_43 = 1 (X4).

Function

44

45

46

47

48

49

50

51

Multistep

Speed Speed Speed Speed Speed Speed Speed Speed

Frequency

8

9

10

11

12

13

14

15

X1 – CM

X2 – CM

X3 – CM

X4 – CM