GE Industrial Solutions AF-300 MICRO-$AVER II User Manual
Page 52
LED
Data
Factory
Customer
Display
Setting
Description
Setting
Setting
6-13
F_33
BRAKING TORQUE SELECTION
0
This sets the limit level for braking torque in accordance
with the brake being used.
0
Low (no Dynamic Braking option)
1
High (with Dynamic Braking option)
NOTE: Always connect an extra braking resistor. Contact
GE Fuji Technical Services for proper brake
resistor option selection.
*F_34
-400
BIAS FREQUENCY
0
to
This function adds the bias frequency offset to the analog
+400
reference frequency to produce the output frequency.
The setting range is between -400 to +400Hz in
steps of 1Hz.
*The bias frequency is only active when the frequency
setting function F_01 = 1
If the bias frequency has been set, the Drive will operate
when an operation command is given, even if the analog
frequency is zero.