Brocade Network OS Command Reference v4.1.0 User Manual

Page 1019

Advertising
background image

Network OS Command Reference

981

53-1003115-01

show rbridge-running config

2

system-monitor fan threshold marginal-threshold 1 down-threshold 2

system-monitor fan alert state removed action raslog

system-monitor power threshold marginal-threshold 1 down-threshold 2

system-monitor power alert state removed action raslog

system-monitor temp threshold marginal-threshold 1 down-threshold 2

system-monitor cid-card threshold marginal-threshold 1 down-threshold 2

system-monitor cid-card alert state none action none

system-monitor sfp alert state none action none

system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0

system-monitor MM threshold marginal-threshold 1 down-threshold 0

system-monitor LineCard threshold marginal-threshold 1 down-threshold 2

system-monitor LineCard alert state none action none

system-monitor SFM threshold marginal-threshold 1 down-threshold 2

no protocol vrrp

no protocol vrrp-extended

interface Ve 123

shutdown

!

!

interface Management 1/0

no ip address dhcp

ip address 10.17.10.21/20

ip gateway-address 10.17.0.1

no ipv6 address autoconfig

no ipv6 address dhcp

!

interface TenGigabitEthernet 1/0/1

description LC 1/0/1-23

fabric isl enable

fabric trunk enable

no shutdown

!

interface TenGigabitEthernet 1/0/2

description LC 1/0/1-23

fabric isl enable

fabric trunk enable

no shutdown

!

interface TenGigabitEthernet 1/0/3

mtu 9216

description LC 1/0/1-23

fabric isl enable

fabric trunk enable

See Also