Show chassis – Brocade Network OS Command Reference v4.1.0 User Manual

Page 740

Advertising
background image

702

Network OS Command Reference

53-1003115-01

show chassis

2

show chassis

Displays all field-replaceable units (FRUs).

Synopsis

show chassis [rbridge-id rbridge-id ]

Operands

rbridge-id rbridge-id

Specifies an RBridge ID for the switch.

Defaults

None

Command Modes

Privileged EXEC mode

Description

Use this command to display the Field Replaceable Unit (FRU) header content for each object in
the chassis. Use this command to display the following information per line:

Chassis name and model, for example, BR-VDX6720-24.

The chassis backplane revision.

Object type: MM (management module), SFM (switch fabric module), LC (line card), CHASSIS,
FAN, POWER SUPPLY, SW CID (chassis ID), WWN (world wide name), or UNKNOWN.

Object number: Slot number (for blades), Unit number (for everything else).

If the FRU is part of an assembly, a brief description displays in parentheses.

FRU header version number (Header Version: x) or blade version.

The object's maximum allowed power consumption: a positive value for power supplies and a
negative value for consumers. Power Consume Factor: -xxx.

A real-time power usage value is displayed for each FRU that supports real-time power
measurement. When the capability is not supported for a FRU, the line is suppressed.
Power Usage is displayed in Watts:

Part number (up to 14 characters): Factory Part Num: xx-xxxxxx-x x

Serial number (up to 12 characters): Factory Serial Num: xxxxxxxxxx

FRU manufacture date: Manufacture: Day: dd Month: mm Year: yyyy

Date of the last FRU header update: Update: Day: dd Month: mm Year: yyyy

Cumulative time, in days, that the FRU has been inserted in the chassis with Network OS
running: Time Alive :dd days

Current time, in days, since the FRU was last powered on or the system was restarted:
Time Awake: dd days

Airflow direction (Brocade VDX 6710, 6720, 6730).

Externally supplied ID (up to 10 characters): ID: xxxxxxxxxx

Externally supplied part number (up to 20 characters): Part Num: xxxxxxxxxxxxxxxxxxx

Externally supplied serial number (up to 20 characters): Serial Num: xxxxxxxxxxxxxxxxxxx

Externally supplied revision number (up to 4 characters): Revision Num: xxxx

Usage Guidelines

This command is executed on the local switch and is supported only on the local switch. The
output of this command depends on the platforms on which it is executed. Not all information is
available for all platforms. In cases where information is not available, the lines are suppressed

Pagination is not supported with this command. Use the “more” parameter to display the output
one page at a time.

Advertising