Brocade Network OS Command Reference v4.1.0 User Manual

Page 955

Advertising
background image

Network OS Command Reference

917

53-1003115-01

show logging raslog

2

To display all RASLog messages for an interface module:

switch# show logging raslog blade LC2

NOS: 3.0.0

2012/05/28-12:07:41, [HASM-1004], 822, L2, INFO, VDX8770-4, Processor rebooted -

Reset

2012/05/28-12:07:41, [HASM-1104], 823, L2, INFO, VDX8770-4, Heartbeat to M1 up

2012/05/28-12:07:48, [HASM-1108], 830, L2, INFO, VDX8770-4, All service instances

become active.

2012/05/29-13:32:50, [HASM-1004], 2721, L2, INFO, VDX8770-4, Processor rebooted -

Reset

To display warning messages only on the standby management module:

switch# show logging raslog blade MM1 severity warning

NOS: 3.0.0

2012/03/09-15:20:55, [FW-1042], 26, M1, WARNING, dutA1-sw0, Sfp TX power for port

1/2/9, is below low boundary(High=1999, Low=125). Current value is 17 uW.

2012/03/09-15:20:55, [FW-1046], 27, M1, WARNING, dutA1-sw0, Sfp Current for port

1/2/9, is below low boundary(High=10, Low=3). Current value is 0 mA.

2012/03/09-15:20:55, [FW-1042], 28, M1, WARNING, dutA1-sw0, Sfp TX power for port

1/2/17, is below low boundary(High=1999, Low=125). Current value is 18 uW.

(output truncated)

To display only the FFDC messages:

switch# show logging raslog attribute FFDC rbridge-id 1

NOS: 3.0.0

1970/01/01-00:09:43, [HASM-1200], 106, MM1 | FFDC, WARNING, chassis, Detected

termination of process Dcmd.Linux.powe:1660

See Also

clear logging raslog, logging raslog console

Advertising