background image

AT-S63 Management Software Menus Interface User’s Guide

Section I: Basic Features

169

The Create LACP (IEEE 8023ad) Aggregator menu is shown in Figure
47.

Figure 47. Create LACP (IEEE 8023ad) Aggregator Menu

5. Configure the following parameters as necessary:

1 - Aggregator
Specifies a name for the aggregator. The name can be up to 20
alphanumeric characters. Spaces are allowed, but special characters,
such as asterisks and exclamation points, are not. Each aggregator
must have a unique name.

2 - Adminkey
Specifies a unique adminkey value for the aggregator. The value is
entered in hexadecimal. The range is 1 to FFFF. For background
information, refer to “Adminkey Parameter” on page 154.

Note

When you create a new aggregator you can specify either the
aggregator’s name or adminkey, but not both. If you specify a name,
the adminkey is based on the operator key of the lowest numbered
port in the aggregator.

If you specify an adminkey, the default name is DEFAULT_AGG
followed by the port number of the lowest numbered port in the
aggregator. For example, an aggregator of ports 12 to 16 is given
the default name DEFAULT_AGG12.

Allied Telesyn Ethernet Switch AT-9400 Series - AT-S63

Marketing

User: Manager

11:20:02 02-Mar-2005

Create LACP (IEEE 802.3ad) Aggregator

1 - Aggregator ..................
2 - Adminkey .................... 0x0000
3 - Distribution Mode ........... SRC/DST MAC
4 - Port Range ..................
C - Create Aggregator

R - Return to Previous Menu

Enter your selection?