Output Module: Activates the output device when faces are detected under Mask Filter or

when the system is unable to detect faces under Mask Filter (Inverse Alarm). Assign an

output module and pin number for the device.

„

Never Recycle: Prevents recorded events from being recycled when the disk becomes full.

5. Click

the

Test button to see if the settings have been configured according to your preference. If

you have set a detection interval, the test will only run for the number of seconds you specified.

6.

To activate the function at certain times only, click the Schedule button and select Active
Schedule
. For details, see Video Analysis Schedule later in this chapter.

7. Click

OK to apply the settings.

8.

Start monitoring to run the application.

Note:

1. Events triggered under Mask Filter or Mask Filter (Inverse alarm) will be recorded to the

System Log, and can be played back in ViewLog. In the System Log, the events are recorded as

Face Count under the Event column.