CCTV Camera Pros Geovision 8.5 Multicam Digital Surveillance System User Manual

Page 211

Advertising
background image

Video

Analysis

193

3

„

Tolerance Time of Alarm: Sets the duration of scene change before an alarm condition is

activated.

„

Automatically Disable Alarm: Stops all types of triggered alerts, including sound alarm,

flashing boxes and output module after the specified duration. Disabling the alerts will not

disable alert settings and the detection in progress.

„

Skip Instant Light Change: Ignores sudden illumination changes and avoids false alarms.

For example, light switches can cause illumination changes suddenly. With the option

selected, the system will ignore significant illumination changes without triggering the alarm

and continue monitoring. See the Note in Crowd Detection earlier in this chapter for possible

risk.

„

Invoke Alarm: Enables the computer alarm when the scene change is detected. Click the […]

button next to the option to assign a .wav sound file.

„

Output Module: Activates the output device when the scene change is detected. Click the […]

button next to the option to assign an installed output module and a pin number.

„

Never Recycle: Enables the system not to recycle the event files of scene change.

4. You

can

click

Test to test your settings. If the scene change cannot be detected, increase

Sensitivity value to increase system sensitivity to changes in the camera view.

5. To activate the function at certain times only, click the Schedule button and select Active

Schedule. For details, see Video Analysis Schedule later in this chapter.

6. Click

OK to apply the settings.

7. Start monitoring to run the application.

When a scene change is detected in the camera view for the specified time, its location will be

highlighted in live video, the selected alarm or output will be activated, and the event will be recorded

as Advanced Scene Change in System Log for later retrieval.

Advertising