I /O Applications


299

6

6.3.2 Moving PTZ Camera to a Preset Location upon Input

Trigger

This feature allows you to define how the PTZ camera and the GV-System will respond to an input

trigger event.

Figure 6-9

Select an Input number to be set up. Clicking the Finger button can apply the same settings to all

inputs.

„

Preset Go by I/O: Enable the option and select your PTZ camera from the drop-down list.

„

Addr: Specify the address of the PTZ camera.

„

Alarm On: Turns the PTZ camera to a preset point when the input is triggered.

„

Alarm Off: Returns the PTZ camera to a preset point when the triggered input is off.

„

Alarm On Dwell Time: Specify the amount of time the PTZ camera stays at “Alarm On” preset

point, before returning to the “Alarm Off” preset point.

Note: Depending on the capability of the PTZ camera, up to 256 PTZ preset points (ranging from 1 to

256) and addresses (ranging from 0 to 255) can be programmed.