6.6.9 The “Advanced Logical Input Status in Multicam”

Option

If you already set a specific input to trigger a specific output in the Main System, you can decide

whether to apply the simple input-trigger-output setting in the Advanced I/O Panel.

For example, you have set a simple access system in the Main System: Input 2 (card reader) triggers

Output 3 (the door opens).

I/O

Device

Setup

I/O

Application

Setting

Figure 6-32

But to tighten security, you may set a group “Garage” in the Advanced I/O Panel. Both Input 1 (power

switch) and Input 2 (card reader) should be activated together to trigger Output 1 (light), Output 2

(alarm) and Output 3 (the door opens) in a cascade series. Simply activating Input 2 (card reader)

shouldn’t cause any output triggers in the cascading hierarchy.

power switch

card reader

light

alarm
door opens

Output 3 door opens

Figure 6-33

So now you have the options:

¾

At default, the simple input-trigger-output setting is applied at the Advance I/O Panel when I/O

monitoring is activated. For this example, Input 2 will trigger Output 3.

¾

To only apply the cascade triggers set in the Advanced I/O Panel and ignore the simple

input-trigger-output setting, enable Use adv. Logical input result as input status from the I/O

icon on the main screen and Enable advanced logical input in Multicam from a certain group

(see Figure 6-19) together.

¾

To switch to the simple input-trigger-output setting, just disable Enable advanced logical input in

Multicam.