I /O Applications


301

6

6.3.4 Deactivating Alarm and Alert Settings upon Input

Trigger

The option lets you instantly deactivate all the prior alarm and alert settings (Output, Wave Alarm, Send

Alerts), when an assigned input module is triggered.

Figure 6-11

[Deactivate notification when selected pin is ON] When an assigned input module is activated, all

designated alarms and alerts will be disabled. Assign an installed input module and a pin number for

the application.

[Deactivate Notification]

„

Triggered by: Select an alert condition from the drop-down list for the application. For example, if

you choose Motion, all designated alarms and alerts upon motion detection will be deactivated

when the assigned input module is activated.

„

Deactivate Selected Notification: Select the alarms and alerts you want to be deactivated, such

as Output, Wave Alarm and/or Send Alert, when the assigned input module is activated.