Configuration and Activation 6-15

Blanking (auto) Select this checkbox to ensure the monitor
disregards depths occurring within a distance from the face of
the ultrasonic depth sensor equivalent to 5 percent of the range
from the sensor face to the bottom of the pipe. This (default)
setting effectively represents the vast majority of pipe/flow
conditions. Therefore, ADS strongly recommends selecting this
option for most applications.

Blanking (override) Enter the distance from the face of the
ultrasonic depth sensor within which to ignore data potentially
representing erroneous readings. Use this option in place of the
auto-blanking option (above) to designate a distance greater
than
5 percent of the range from the face of the sensor to the
bottom of the pipe. Do not choose a distance shorter than 5
percent of the range. ADS recommends using this option only
when spikes in the data are occurring beyond the 5 percent
range and under direct consultation with an ADS
representative.

Pipe Height This field represents the height of the pipe in
which the sensor is installed. This parameter is not editable
from this location.